35986841_10216840653711318_1105697261150535680_n

EVALUATING FRACTURE RESISTANCE and MARGINAL INTEGRITY of CRYSTAL ULTRA CERAMIC RESIN HYBRID MATERIAL COMPARED to E.MAX- IN VITRO STUDY // MS // Prof. Dr. Nadia Fahmy // Dr. Ahmed Kamal Ebeid (2017-2018) (Record no. 13957)

MARC details
000 -LEADER
fixed length control field 01670nam a22002177a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190307094348.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 180801b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Transcribing agency MSA
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 616
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Christine George Henry
245 ## - TITLE STATEMENT
Title EVALUATING FRACTURE RESISTANCE and MARGINAL INTEGRITY of CRYSTAL ULTRA CERAMIC RESIN HYBRID MATERIAL COMPARED to E.MAX- IN VITRO STUDY // MS // Prof. Dr. Nadia Fahmy // Dr. Ahmed Kamal Ebeid (2017-2018)
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Giza
Name of publisher, distributor, etc. MSA
Date of publication, distribution, etc. 2018
300 ## - PHYSICAL DESCRIPTION
Extent 7 P.
Dimensions 30 CM.
440 ## - SERIES STATEMENT/ADDED ENTRY--TITLE
Title DENTISTRY DISTINGUISHED PROJECTS 2018
500 ## - GENERAL NOTE
General note MSA Post Graduate Studies
520 ## - SUMMARY, ETC.
Summary, etc. Hybrid Ceramics have been recently introduced where<br/>ceramics have been combined with composite resins to solve<br/>the brittleness property of ceramics as well as providing<br/>modulus of elasticity close to that of dentine. A newly launched<br/>hybrid restorative material claimed to be the strongest<br/>restorative material in terms of compressive and flexural<br/>strength. The purpose of this study was designed to compare<br/>the marginal integrity and facture resistance of 3-unit e.max<br/>and Crystal Ultra FDP after thermocycling. Conclusion: Crystal<br/>Ultra Fixed Dental Prosthesis presented statistically higher<br/>mean marginal integrity values after aging than the IPS e.max<br/>CAD group. Fracture resistance of IPS e.max CAD group<br/>displayed statistically significant higher mean value than the<br/>Crystal Ultra group
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Dentistry
Form subdivision CRYSTAL ULTRA CERAMIC
General subdivision EVALUATING FRACTURE
Chronological subdivision MARGINAL INTEGRITY
856 ## - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://drive.google.com/file/d/1Io8MPvgHxZF2QWlAAw9NP_vaFHUSlJIu/view?usp=sharing">https://drive.google.com/file/d/1Io8MPvgHxZF2QWlAAw9NP_vaFHUSlJIu/view?usp=sharing</a>
Public note FULL TEXT PRESS HERE
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Master's degree or PHD
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     Centeral Library Centeral Library Soft Copy located on library Cataloge 01.08.2018   MS29DENT2018 81947-1 01.08.2018 01.08.2018 Master's degree or PHD