35986841_10216840653711318_1105697261150535680_n
Normal view MARC view ISBD view

Implant Retained Mandibular Overdenture using Locator Attachment \\ GP \\ DR. Samer Mostafa ( 2017-2018 )

By: Menna-Allah Abo Zaid. 142919.
Contributor(s): Shereen Wagdy [Supervisor. ] | Ahmed Hossam [Supervisor. ] | AL. Mohamed Abou Heikal [Supervisor. ] | Ahmed Younis. (144501) [Additional Author. ] | Tasneem Abdel Hafez. (141985) [Additional Author. ].
Material type: materialTypeLabelBookSeries: DENTISTRY DISTINGUISHED PROJECTS 2018. Publisher: Giza: MSA, 2018Description: 12 p. :, 26 CM.Subject(s): Dental ImplantOnline resources: Full text click here Summary: A 52 years old female patient came to MSA clinics complaining from an ill-fitting lower single denture, opposed by bilateral fixed bridges. Radiographic examination through CBCT revealed adequate bone height and narrow width anteriorly. Implants were planned to be inserted bilaterally at the lower first premolar areas for their adequate width. Bilateral surgical flaps were reflected at the planned areas, and implants were inserted using the pre-fabricated surgical guide after sequential drilling. Implants left for 3 months for osseointegration, then Pick-up impression technique was made for the locator attachment to provide denture retention provided that it is accurately positioned regarding occlusion
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode
Distinguished Graduation Projects Distinguished Graduation Projects Soft Copy located on library Cataloge GP14DENT2018 (Browse shelf) Available 81895

A 52 years old female patient came to MSA clinics complaining from an ill-fitting lower
single denture, opposed by bilateral fixed bridges. Radiographic examination through
CBCT revealed adequate bone height and narrow width anteriorly. Implants were
planned to be inserted bilaterally at the lower first premolar areas for their adequate
width. Bilateral surgical flaps were reflected at the planned areas, and implants were
inserted using the pre-fabricated surgical guide after sequential drilling. Implants left
for 3 months for osseointegration, then Pick-up impression technique was made for
the locator attachment to provide denture retention provided that it is accurately
positioned regarding occlusion